[¹Ì±¹] Ç÷οì Å×Å©, ÃÊÀú À¯·® ÀúÁ¡µµ ¾×ü ÀÀ¿ë Á¦Ç° À§ÇÑ ÀζóÀÎ ÃÊÀ½ÆÄ ÃøÁ¤±â Ãâ½Ã
À̸§ °ü¸®ÀÚ waterindustry@hanmail.net ÀÛ¼ºÀÏ 2020.03.31 Á¶È¸¼ö 463
ÆÄÀÏ÷ºÎ

[¹Ì±¹] Ç÷οì Å×Å©, ÃÊÀú À¯·® ÀúÁ¡µµ ¾×ü ÀÀ¿ë Á¦Ç° À§ÇÑ  ÀζóÀÎ ÃÊÀ½ÆÄ ÃøÁ¤±â Ãâ½Ã

 


Á¤¹Ð À¯·® ÃøÁ¤±â±â, ½Ã½ºÅÛ ¹× ±³Á¤±âÀÇ ´ëÇ¥ÀûÀÎ Á¦Á¶¾÷üÀÎ ÇÁ·Î¿ì Å×Å©³î·¯Áö»ç(Flow Technology, Inc.; FTI)´Â  ÃÊÀú À¯·® ÀúÁ¡µµ ¾×ü ÀÀ¿ë Á¦Ç°¿¡ »ç¿ëÇϱâ À§ÇÑ 'QLF ½Ã¸®Áî' ÀζóÀÎ ÃÊÀ½ÆÄ À¯·®°è¸¦ Ãâ½ÃÇß´Ù.


'QLF ¹ÌÅÍ'ÀÇ ³ôÀº Á¤È®¼º°ú ¹Ýº¹¼ºÀº À¯·®ÀÌ Á¶ÀýµÇ°í 'µ¨Å¸(Delta) T'°¡ ÃàÀ» µû¶ó ÃøÁ¤µÇ´Â ¹ÌÅÍ º»Ã¼ ³»ÀÇ °íÀ¯ ÇÑ ÃøÁ¤ ¼½¼ÇÀ» ÅëÇØ ´Þ¼ºµÈ´Ù. 


¹ÌÅÍÀÇ ÀÛµ¿ ¿ø¸®´Â È帣´Â ¸Åü¿Í ÇÔ²² ±×¸®°í È帣´Â ¸Åü·Î À̵¿ÇÏ´Â ÃÊÀ½ÆÄÀÇ ½ÃÂ÷¸¦ ÃøÁ¤ÇÑ´Ù. ½Ã°£ Â÷ÀÌ´Â À¯Ã¼ÀÇ À¯·®¿¡ Á¤ºñ·ÊÇÑ´Ù. ¿Âµµ´Â À¯·®°è º»Ã¼¿¡ ³»ÀåµÈ RTD¸¦ ÅëÇØ ÃøÁ¤µÈ´Ù.

 

375_250-375_250_thumbnail_pr_fti_introduces_qlf_series_ultrasonic_flowmeter_hr.png

ÀúÁ¡µµ Àú À¯·® ÀÀ¿ë ºÐ¾ß¸¦ À§ÇÑ QLF ½Ã¸®Áî ÀζóÀÎ ÃÊÀ½ÆÄ À¯·®°è.


'QLF ÀζóÀÎ ÃÊÀ½ÆÄ À¯·®°è'´Â Ç×°ø¿ìÁÖ, ³ó¾÷, ÀÚµ¿Â÷, È­ÇÐ, ¼®À¯ ¹× °¡½º, »ê¾÷, Á¦¾à µî ¿©·¯ »ê¾÷¿¡¼­ ÃÊÀú·ù À¯·®À» ÃøÁ¤Çϱâ À§ÇÑ ÀÛ°í °ß°íÇÏ¸ç ´ÙÀç´Ù´ÉÇÏ¸ç ºñ¿ë È¿À²ÀûÀÎ ¼Ö·ç¼ÇÀÌ´Ù. ÀÌ °è·®±âÀÇ ±¸Á¶´Â ¸¹Àº °í¼øµµ ºÎ½Ä¼º À¯Ã¼¿¡ ´ëÇÑ ¼±Åà °è·®±â¸¦ ¸¸µç´Ù.


´ëÇ¥ÀûÀÎ ÃøÁ¤ Àû¿ë »ç·Ê·Î´Â ¼ÒÇü ¿£Áø ¿¬·á ¼Òºñ·®, È­ÇÐ ÁÖÀÔ ½Ã½ºÅÛ, ³Ã°¢Å¾, º¸ÀÏ·¯ ¹× ¸· ¿©°ú ½Ã½ºÅÛÀ» À§ÇÑ ¼öó¸® È­ÇÐ ½ºÅ°µå ¹× »ùÇà ½ºÅ×À̼Ç, Ç×°ø±â ¿¬·á È帧 ½ºÅĵå, µðÁ© ¹è±â¾×(DEF) ¼Òºñ·®, ¾×ü Å©·Î¸¶Åä±×·¡ÇÇ, »çÀÌµå ½ºÆ®¸² ¿©°ú °°Àº °ÍÀÌ ÀÖ´Ù.


ÇÁ·Î¿ì Å×Å©³î·¯Áö(Flow Technology) ¸¶ÄÉÆà ¸Å´ÏÀúÀÎ ¸ÅÆ® ÀÚÀÛ(Matt Zajac)Àº "QLFÀÇ ±¸Á¶, ¶Ù¾î³­ Á¤È®¼º, ¸Å¿ì ³·Àº Á¡µµÀÇ ¾×üÀÇ À¯·®À» ÃøÁ¤ÇÏ´Â ´É·ÂÀº ´Ù¾çÇÑ ÀÀ¿ë ºÐ¾ß¿Í »ê¾÷¿¡ ¸Å¿ì ÀûÇÕÇÏ´Ù"°í ¸»Çß´Ù.


¼ÒÇü QLF ÃÊÀ½ÆÄ ÃøÁ¤±â¿¡´Â ¿òÁ÷ÀÌ´Â ºÎÇ°µµ ¾ø°í, ½À±â°¡ ¾ø´Â ¼¾¼­µµ ¾øÀ¸¸ç, À¯·® È帧ÀÇ Àå¾Ö¹°µµ ¾ø¾î ¾Ð·Â °­Çϸ¦ Áõ°¡½ÃÅ°´Â ¿øÀÎÀÌ µÈ´Ù. 1/8ÀÎÄ¡ ¹è°ü¿¡ »ç¿ëÇÒ ¼ö ÀÖÀ¸¸ç, ¹ÌÅͱâÀÇ À¯·®Àº 0.001¡­3.5 GPMÀÌ´Ù.


Æǵ¶°ªÀÇ +/-0.5%+¾ÈÁ¤¼º Á¦·Î±îÁö Á¤È®Çϸç, ¹Ýº¹¼ºÀº 10:1 ÅÏ´Ù¿î ´ëºñ +/-0.2%ÀÌ´Ù. ¹ÌÅͱâ´Â È­¾¾ 14µµ¡­176µµ(¼·¾¾ ¿µÇÏ 10µµ¡­80µµ)ÀÇ ¿Âµµ ¹üÀ§¸¦ ´Ù·ç¸ç ¾Æ³¯·Î±×, ½ºÄÉÀϸµ ÁÖÆļö ¹× Modbus RTU Ãâ·ÂÀ» °¡Áö°í ÀÖ´Ù.


¡á ÇÁ·Î¿ì Å×Å©³î·¯Áö»ç(Flow Technology, Inc.; FTI) ¼Ò°³
ÇÁ·Î¿ì Å×Å©³î·¯Áö»ç(Flow Technology, Inc.; FTI)´Â 50³â ÀÌ»óÀÇ È帧 ÃøÁ¤ °æÇèÀ» ¹ÙÅÁÀ¸·Î ¼³°è, Á¦Á¶ ¹× ¼­ºñ½º ºÐ¾ß¿¡¼­ ÃÖ°í Ç°Áú ±âÁØÀ» À¯ÁöÇÏ°í ÀÖ´Ù.


±×°ÍÀÇ Á¦Ç° ¶óÀο¡´Â ³ÐÀº ¹üÀ§ÀÇ Åͺó, ¾ç±Ø º¯À§, ÀüÀÚ±â, ÀζóÀÎ ¹× Ŭ·¥ÇÁ¿Â ÃÊÀ½ÆÄ À¯·®°è, À¯·® ±³Á¤±â, À¯·® Á¦¾î±â ¹× º¸Á¶ ÀüÀÚ ÀåÄ¡°¡ Æ÷ÇԵȴÙ.


´ëÇ¥ÀûÀÎ ÀÀ¿ë ºÐ¾ß´Â Ç×°ø¿ìÁÖ, ÀÚµ¿Â÷, »ê¾÷, °è·®ÇÐ, ¼®À¯ ¹× °¡½º, ¼öó¸®, À§»ý ºÐ¾ß¿¡¼­ ã¾Æº¼ ¼ö ÀÖ´Ù.


¶ÇÇÑ, ¼¼°è ÃÖ´ë ±Ô¸ðÀÇ 1Â÷ Ç¥ÁØ À¯·®°è ±³Á¤ ±â¼ú Áß Çϳª¸¦ À¯ÁöÇÏ°í ÀÖÀ¸¸ç, ¿ÏÀüÇÑ À¯·®°è ±³Á¤, ¼­ºñ½º, ¼ö¸®¸¦ Á¦°øÇÏ°í ÀÖ´Ù.


Flow Technology, Inc.´Â NVLAP°¡ Àΰ¡ÇÑ ISO 9001 & AS9100¿¡ µî·ÏµÇ¾î ÀÖÀ¸¸ç, ISO/IEC 17025, MIL-STD-45662A ¹× ANSI Z 540¿¡ ´ëÇÑ ±³Á¤ Áؼö¸¦ °¡Áö°í ÀÖ´Ù.

 

[¿ø¹®º¸±â]


Flow Technology Introduces In-Line Ultrasonic Meter For Ultra-Low-Flow Low Viscosity Liquid Application

 

 

Flow Technology, Inc. (FTI), a leading manufacturer of precision flow measurement instruments, systems and calibrators, has introduced the QLF Series in-line ultrasonic flow meter for use in ultra-low-flow low viscosity liquid applications.


The QLF meter¡¯s high accuracy and repeatability is achieved through the unique measurement section within the meter body where flow is conditioned and Delta T measured along its axis.


The meter¡¯s principle of operation measures the time difference of an ultrasonic wave traveling with and against the flowing medium.


The time difference is directly proportional to the fluid¡¯s flow rate. Temperature is measured via an RTD embedded into the flow meter body.


The QLF in-line ultrasonic flow meter is a compact, rugged, versatile, cost-effective solution for measuring ultra-low flow in a number of industries, such as aerospace, agricultural, automotive, chemical, oil & gas, industrial, and pharmaceutical. The meter¡¯s construction makes it the meter of choice for many high purity and corrosive fluids.


Typical measurement application examples include: Small engine fuel consumption; chemical injection systems; water treatment chemical skids and sample stations for cooling towers, boilers and membrane filtration systems; aircraft fuel flow stands; diesel exhaust fluid (DEF) consumption; liquid chromatography; and side stream filtration.


¡°The QLF¡¯s construction, excellent accuracy, and ability to measure very low flow rates of clean, low viscosity liquid make it a great fit for a range of applications and industries,¡± said Matt Zajac, Flow Technology marketing manager.


The compact QLF ultrasonic meter has no moving parts, non-wetted sensors and no obstructions in the flow stream to cause in increase in pressure drop. Available for 1/8-inch piping, the meter¡¯s flow range is 0.001 to 3.5 GPM.


It is accurate to +/-0.5% of reading plus zero stability, and repeatability is +/-0.2% over 10:1 turndown. The meter handles a temperature range of 14¡ÆF to 176¡ÆF (-10¡ÆC to 80¡ÆC) and has analog, scaled frequency and Modbus RTU outputs.


About Flow Technology, Inc.
With over 50 years of flow measurement experience, Flow Technology, Inc., maintains the highest standards of quality in design, manufacturing and service.


Its product line includes a wide range turbine, positive displacement, electromagnetic, in-line and clamp-on ultrasonic flow meters; flow calibrators, flow controllers and ancillary electronics.


Typical applications are found in the aerospace, automotive, industrial, metrology, oil & gas, and sanitary fields.


In addition, the company maintains one of the world¡¯s largest primary standard flow meter calibration technologies, and provides complete flow meter calibration, service and repair.


Flow Technology, Inc., is registered to ISO 9001 & AS9100, accredited by NVLAP, and has calibration conformance to ISO/IEC 17025, MIL-STD-45662A and ANSI Z 540.


[Ãâó=¿öÅͿ¶óÀÎ(https://www.wateronline.com/doc/flow-technology-introduces-ultrasonic-meter-for-ultra-viscosity-liquid-application-0001) / 2020³â 3¿ù 26ÀÏ]

¨Ï±Û·Î¹ú¹°»ê¾÷Á¤º¸¼¾ÅÍ(www.waterindustry.co.kr) ¹«´ÜÀüÀç ¹× Àç¹èÆ÷±ÝÁö
ÀÌÀü±Û [µ§¸¶Å©] Æó¼öÇ÷£Æ® ¾×Ãß¿¡ÀÌÅÍ ÀÚµ¿È­ À§ÇØ CK ¼¾Æ®·Î´Ð ¸ðµâ½Ä äÅÃ
´ÙÀ½±Û [¹Ì±¹] Greasezilla, ¸ðµâ½Ä FOG ºÐ¸® ½Ã½ºÅÛ Á¦°ø
±Û·Î¹ú¹°»ê¾÷Á¤º¸¼¾ÅÍ.   ¼¾ÅÍÀå : ¹èö¹Î
ÁÖ¼Ò : ¼­¿ï½Ã ¼ÛÆı¸ »ïÀüµ¿ 72-3 À¯¸²ºôµù 5Ãþ TEL (02) 3431-0210   FAX (02) 3431-0260   E-mail waterindustry@hanmail.net
COPYRIGHT(C) 2012 ±Û·Î¹ú¹°»ê¾÷Á¤º¸¼¾ÅÍ. ALL RIGHT RESERVED.