Áñ°Üã±â Ãß°¡     ½ÃÀÛÆäÀÌÁö·Î ¼³Á¤ óÀ½À¸·Î  l  ·Î±×ÀΠ l  È¸¿ø°¡ÀÔ  l  »çÀÌÆ®¸Ê

>
ȸ¿ø°¡ÀÔ   l   ¾ÆÀ̵ð/ºñ¹Ð¹øȣã±â
¡®Á¦38ȸ 2023³â »ó¹Ý±â ...
¡®Á¦37ȸ 2022³â ÇϹݱâ ...
Á¦37ȸ ¡¸2022³â ÇϹݱâ ...
 
HOME > ÇؿܽÃÀåÁ¤º¸ > ÃֽŴº½º
[2013] [NSF] ¿©°¡½Ã¼³ ¼ö󸮸¦ À§ÇÑ ¿ÀÁ¸ ÀåÄ¡ÀÇ ½ÇÇè °ËÁõ
À̸§ °ü¸®ÀÚ waterindustry@hanmail.net ÀÛ¼ºÀÏ 2013.05.01 Á¶È¸¼ö 869
ÆÄÀÏ÷ºÎ
[NSF] ¿©°¡½Ã¼³ ¼ö󸮸¦ À§ÇÑ ¿ÀÁ¸ ÀåÄ¡ÀÇ ½ÇÇè °ËÁõ

´ë±Ô¸ð¿Í ³ôÀº À¯·®ÀÇ ¹° ½Ã½ºÅÛÀ¸·Î, ¿©°¡½Ã¼³ ¼öó¸® ½Ã½ºÅÛÀÇ Ç×±Õ È¿°úÀÇ Á¤È®ÇÑ Æò°¡¸¦ ¾ò´Â °ÍÀº ¾î·Æ´Ù. ½ÇÇè½Ç Å×½ºÆ® ½Ã½ºÅÛÀº ¹° »óÅ ¹× ¼ö¿µÀå¿¡ ÀÖ´Â ÀáÀçÀûÀÎ ¹Ì»ý¹° ¿À¿° ¹°ÁúÀ» ¸ð¹æÇϵµ·Ï ¼³°èµÇ¾ú´Ù.

ÀÌ ½Ã½ºÅÛÀº Å©¸³Å佺Æ÷¸®µð¿ò Æĺç(Cryptosporidium parvum), »ì±Õ¹ÙÀÌ·¯½º MS2 (bacteriophage MS2), ¿£Å×·ÎÄÚÄ¿½º Æä½Ã¿ò(Enterococcus faecium), ³ì³ó±Õ(Pseudomonas aeruginosa)À» Æ÷ÇÔÇÏ´Â ³× °¡Áö ¹Ì»ý¹°¿¡ ´ëÇÑ ÇöÀå ¿ÀÁ¸ »ì±Õ ÀåÄ¡ÀÇ ¼º´ÉÀ» Æò°¡Çϱâ À§ÇØ È°¿ëµÇ¾ú´Ù.


[¿ø¹®º¸±â]

Laboratory validation of an ozone device for recreational water treatment

Robert S. Donofrio, Sal Aridi, Ratul Saha, Robin Bechanko, Kevin Schaefer, Lorelle L. Bestervelt and Beth Hamil

ABSTRACT
Obtaining an accurate assessment of a treatment system's antimicrobial efficacy in recreational water is difficult given the large scale and high flow rates of the water systems. A laboratory test system was designed to mimic the water conditions and potential microbial contaminants found in swimming pools.

This system was utilized to evaluate the performance of an in situ ozone disinfection device against four microorganisms: Cryptosporidium parvum, bacteriophage MS2, Enterococcus faecium, and Pseudomonas aeruginosa. The sampling regimen evaluated the antimicrobial effectiveness in a single pass fashion, with samples being evaluated initially after exposure to the ozone unit as well as at points downstream from the device.

Based on the flow dynamics and log reductions, Ct values were calculated. The observed organism log reductions were as follows: >6.7 log for E. faecium and P. aeruginosa; >5.9 log for bacteriophage MS2; and between 2.7 and 4.1 log for C. parvum. The efficacy results indicate that the test system effectively functions as a secondary disinfection system as defined by the Centers for Disease Control and Prevention's Model Aquatic Health Code.
 
 
¨Ï±Û·Î¹ú¹°»ê¾÷Á¤º¸¼¾ÅÍ(www.waterindustry.co.kr) ¹«´ÜÀüÀç ¹× Àç¹èÆ÷±ÝÁö
ÀÌÀü±Û [NSF] Kruger XTREAM¢â´Â ´õ ¸¹Àº Ç¥¸éÀûÀ» ¾ò´Â´Ù
´ÙÀ½±Û [NSF] ´ç½ÅÀÇ ºÎ¾ý¿¡¼­ °¡Àå ´õ·¯¿î °÷
±Û·Î¹ú¹°»ê¾÷Á¤º¸¼¾ÅÍ.   ¼¾ÅÍÀå : ¹èö¹Î
ÁÖ¼Ò : ¼­¿ï½Ã ¼ÛÆı¸ »ïÀüµ¿ 72-3 À¯¸²ºôµù 5Ãþ TEL (02) 3431-0210   FAX (02) 3431-0260   E-mail waterindustry@hanmail.net
COPYRIGHT(C) 2012 ±Û·Î¹ú¹°»ê¾÷Á¤º¸¼¾ÅÍ. ALL RIGHT RESERVED.