[2013] [ÀÌÅ»¸®¾Æ] ¿À¿°¹°Áú °ËÃâ¿¡ ¿ì¼öÇÑ ¹° È帧
À̸§ °ü¸®ÀÚ waterindustry@hanmail.net ÀÛ¼ºÀÏ 2013.10.24 Á¶È¸¼ö 863
ÆÄÀÏ÷ºÎ
[ÀÌÅ»¸®¾Æ]¿À¿°¹°Áú °ËÃâ¿¡ ¿ì¼öÇÑ ¹° È帧
 
 

»õ·Î¿î µðÀÚÀÎÀÇ ¸¶ÀÌÅ©·ÎÀ¯Ã¼ °¨Áö±â´Â °¡µÖÁöÁö ¾ÊÀº ¹°ÀÇ È帧À» ¾×ü ¼ÓÀÇ À§ÇèÇÑ È­Çй°Áú°ú ¹ÚÅ׸®¾Æ¸¦ ½ÃÇèÇÏ´Â °£´ÜÇÏ°í Àú·ÅÇÑ ¹æ¹ýÀ¸·Î ÀÌ¿ëÇÑ´Ù.

ACQUASENSE¶ó´Â ¿¬±¸ÇÁ·ÎÁ§Æ®·Î ÀÌÅ»¸®¾Æ¿¡¼­ °³¹ßµÈ ÀÌ ¿À¿°¹° °ËÃâ±â´Â ¿À´Ã³¯ÀÇ Áøº¸ÀûÀÎ ¹° °Ë»ç ÀåÄ¡¿¡ ¾²À̴ ä³Î º®À» ¾ø¾Ý´Ù. ±×·¯ÇÑ ÀåÄ¡µéÀº ¹è°æÀâÀ½À» ¹ß»ý½Ãų ¼ö À־ ¸íÈ®ÇÑ Æǵ¶À» ¾î·Æ°Ô ¸¸µç´Ù. ±× ´ë½Å À̹ø ÀåÄ¡´Â Æ©ºê³ª ÆÄÀÌÇÁ¿¡ ÀÇÇØ °¡µÖÁöÁö ¾ÊÀº ¹°ÀÇ Á¼Àº È帧À» ÀÌ¿ëÇϸç, ¹° Á¦Æ®´Â ½Ã·á¿Í äÁýÀåºñÀÇ µÎ ¿ªÇÒÀ» °âÇÑ´Ù. ¡°ÀÌ °¨Áö±âÀÇ Çõ½ÅÀûÀÎ ¸é¸ð´Â ºûÀ» ¼öÁýÇϴµ¥ ¾²ÀÌ´Â ´Ü¼øÇÏ°íµµ ±³¹¦ÇÑ ¹æ¹ý°ú °ü·Ã ÀÖ´Ù. ±×°ÍÀº ¹°ÀÇ È帧¡±À̶ó°í ÀÌÅ»¸®¾Æ ±¹¸³¿¬±¸À§¿øȸ IREA(Institute for Electromagnetic Sensing of the Environment)ÀÇ Áö¾È·çÄ« Æ丣½ÃüƼ(Gianluca Persichetti)´Â ¸»Çß´Ù.

ÀüÇüÀûÀÎ ¸¶ÀÌÅ©·ÎÀ¯Ã¼ °ËÃâ±âµéÀº Çü±¤ À¯±â È¥ÇÕ¹°·Î ¹° ½Ã·á¸¦ ºÙÀâ°í Á¶Á¾ÇÏ´Â Á¼Àº ä³Î¿¡ ÀÇÁ¸ÇÑ´Ù. ±×·¯³ª ¹°¼ÓÀÇ ¹ÚÅ׸®¾Æ¿Í È­Çй°ÁúÀ» ºñÃß´Â ·¹ÀÌÀú ºûÀº ä³Î º®µµ ºñÃ߱⠶§¹®¿¡, ·¹ÀÌÀú ºûÀÌ »ê¶õµÇ¾î Çü±¤ ¿À¿°¹°Áú°ú ¹è°æÀâÀ½ »çÀÌÀÇ ±¸º°À» ¸ðÈ£ÇÏ°Ô ¸¸µç´Ù. º®ÀÇ ¸¶¸ð ¶ÇÇÑ ÀÌ·¯ÇÑ ±â±¸¸¦ ÀÌ¿ëÇÏ¿© ¼öÇàµÈ ÃøÁ¤ÀÇ ½Å·Ú¼ºÀ» ¾àÈ­½ÃŲ´Ù. ÀÌ·± ¹æ½Ä ´ë½Å, Æ丣½ÃüƼ¿Í µ¿·áµéÀº °£´ÜÈ÷ ±×·¯ÇÑ °ÍµéÀ» Á¦°ÅÇϱâ·Î °áÁ¤Çß´Ù. À̹ø »õ ±â¼ú¿¡¼­´Â ¹° ½Ã·á¸¦ ³ëÁñÀ» ÅëÇØ ÃÊ´ç 1.4¹ÌÅÍ·Î ÆßÇÎÇÏ¿© Á÷°æÀÌ 1¹Ð¸®¹ÌÅͺ¸´Ù ÀÛÀº Á¼Àº È帧À» ¸¸µç´Ù. ±×·± µÚ ±×µéÀº ³ëÃâµÈ ¹° Á¦Æ® À§·Î UV ·¹ÀÌÀú¸¦ ºñÃá´Ù. ¿À¿°¹°Áú°ú ¹ÚÅ׸®¾Æ¿¡¼­ ¹ß»ýµÈ Çü±¤ ºûÀÌ ÁÖÀ§·Î Æ¢¾î³ª¿Í Á¦Æ® ³»ºÎ¿¡ Æ÷ȹµÇ°í, Á¦Æ®´Â µµÆÄ·ÎÀÇ ¿ªÇÒÀ» ÇÔÀ¸·Î½á ºûÀÌ ¹° È帧À» ÅëÇØ Àü´ÞµÇµµ·Ï ¸¸µç´Ù.

·¹ÀÌÀú ±¤Àº ½ÅÈ£¸¦ È帮°Ô ¸¸µé ¼ö ÀÖ´Â ¹è°æ ÀâÀ½¿øÀ̱⵵ ÇϹǷÎ, ¹° È帧¿¡ ¼öÁ÷ÀÎ °¢µµ·Î ·¹ÀÌÀú ºöÀ» ¹ß»çÇÔÀ¸·Î½á Á¦Æ®¿¡ Æ÷ȹµÈ ºûÀÇ ¾çÀ» ÃÖ¼ÒÈ­Çß´Ù°í Æ丣½ÃüƼ´Â ¸»Çß´Ù. 16mm¸¦ ÁøÇàÇÑ µÚ, Á¦Æ®´Â Çü±¤ ºû ½ÅÈ£¸¦ ¼öÁýÇÏ´Â ±¤¼¶À¯¸¦ Æ÷ÇÔÇÏ´Â ÀÛÀº ÆÄÀÌÇÁ ¼ÓÀ¸·Î µé¾î°£´Ù. ¹°Àº °Å²Ù·Î ÆßÇÎµÇ¾î ³ëÁñÀ» ÅëÇØ Àç¼øȯµÊÀ¸·Î½á, ¼Ò·®ÀÇ ½Ã·áÁ¶Â÷µµ ±ä ½Ã°£ µ¿¾È ºÐ¼®ÇÒ ¼ö ÀÖ°Ô µÈ´Ù.

¿¬±¸ÁøÀº ÁöÇϼöÀÇ ÁÖ¿ä ¿À¿°¹°Áúµé Áß ÀϺÎÀÎ º¥Á¨, Åç·ç¿£, Å©½Ç·»°ú °°Àº Åä¾ç ¿À¿°¹°Áú°ú Ÿ¸£¿Í ¼®À¯¿¡¼­ ¹ß°ßµÇ´Â À¯ÇØ ¹ß¾Ï¼º È­Çй°ÁúÀÎ ´Ùȯ ¹æÇâÁ· źȭ¼ö¼Ò(polycyclic aromatic hydrocarbons)¸¦ ´Ù¾çÇÑ ¾çÀ¸·Î ÀÌ ÀåÄ¡·Î ½ÃÇèÇÏ¿´°í, ÀÌ ÀåÄ¡°¡ ±Øµµ·Î ¹Î°¨ÇÏ´Ù´Â °ÍÀ» ¹ß°ßÇß´Ù. ÀÌ ÀåÄ¡´Â EPA(Environmental Protection Agency)°¡ Çã¿ëÇÏ´Â °Íº¸´Ù ´õ ³·Àº ¼öÁØÀÇ ¿À¿°¹°Áúµµ °ËÃâÇÒ ¼ö ÀÖ¾ú´Ù. ¶ÇÇÑ ÀÌ ÀåÄ¡´Â źÀúº´À» À¯¹ßÇÏ´Â °Í°ú ºñ½ÁÇÑ À¯ÇØ ¹ÚÅ׸®¾ÆÀÎ °íÃʱÕ(Bacillus subtilus)µµ °¨ÁöÇÒ ¼ö ÀÖ¾ú´Ù.

ÇöÀçÀÇ ÀåÄ¡¿¡´Â ƯÁ¤ È­Çй°ÁúÀÇ ±¤ÇÐÀû Ư¡À» ÃøÁ¤ÇÏ´Â ºÐ±¤°è°¡ ´Þ·Á ÀÖ´Ù. ¿¬±¸ÁøÀº ÇâÈÄ ¹° ¾ÈÀü¼º °Ë»ç ºÐ¾ß¿¡¼­ »ó¿ëÈ­Çϱâ À§Çؼ­, ·¹ÀÌÀú¸¦ LED·Î ¹Ù²Ù°í ºÐ±¤°è¸¦ ´õ °£´ÜÇÏ°í ´ú °ªºñ½Ñ ±¸¼ºÀ¸·Î ´ëüÇÏ¿© ÀÌ ÀåÄ¡¸¦ ´õ Àú·ÅÇÏ°í ÀÛ°Ô Á¦ÀÛÇÒ °èȹÀÌ´Ù. ±×·¯ÇÑ ±¸¼º¿¡´Â ½ÅÈ£¸¦ °ËÃâÇϱâ À§ÇØ ¿øÄ¡ ¾Ê´Â ¹è°æ ±¤À» Á¦°ÅÇÏ´Â ÇÊÅÍ¿Í ºûÀ» Àü±â·Î ¹Ù²Ù´Â ±¤´ÙÀÌ¿Àµå°¡ Æ÷Ç﵃ °ÍÀÌ´Ù. ¹° ¾ÈÀü ºÐ¾ß ¿Ü¿¡µµ, ¹Ì·¡ÀÇ Àåºñ´Â ´Ù¾çÇÑ È­Çй°ÁúÀ̳ª »ýÀÇÇבּ¸¿ë ¹ÚÅ׸®¾Æ ¼¼Æ÷µéÀ» ±¸º°Çϱâ À§ÇÑ ´õ¿í Á¤±³ÇÑ °¨Áö±â·Î ¼³°èµÉ ¼ö ÀÖ´Ù°í Æ丣½ÃüƼ´Â ¸»Çß´Ù.
 
[Ãâó : KISTI ¹Ì¸®¾È(http://mirian.kisti.re.kr) ¡º±Û·Î¹úµ¿Çâºê¸®ÇÎ(GTB)¡»2013. 10. 24]
 
 
[¿ø¹®º¸±â]
 
Water Stream Detects Pollution Better
 
NAPLES, Italy, Oct. 15, 2013 — A microfluidic sensor with a novel design uses unconfined streams of water as a simple, cheap way to test for dangerous chemicals and bacteria in liquid.
 
The pollutant detector, developed in Italy within the framework of the research project ACQUASENSE, forgoes the walls of channels used in today's more advanced water testing devices, which can produce background noise that makes getting a clear reading difficult. Instead, it favors a narrow stream of water unconfined by tubes or pipes, with the water jet doubling as both the sample and the collection equipment.
 
"The innovative aspect of this sensor is related to the simple and tricky way used to collect the light — a water stream," said Gianluca Persichetti of the Institute for Electromagnetic Sensing of the Environment (IREA), National Research Council, (CNR) in Italy.
 
Typical microfluidic detectors rely on narrow channels to hold and control the water samples with their fluorescing organic compounds. But the laser light that illuminates bacteria and chemicals in the water also shines on the channel walls, where it scatters and obscures the distinction between the fluorescing contaminants and their background. Wear and tear on the walls also weakens the reliability of measurements made using these instruments.
 
Instead, Persichetti and his colleagues in the group led by Romeo Bernini decided simply to do away with them. In their new technique, they pump the water sample through a nozzle at 1.4 meters per second, producing a narrow stream that is less than a millimeter in diameter. Then they shine a UV laser onto the exposed jet of water. The fluorescent light produced by the pollutants and bacteria bounces around and is trapped inside the jet, which acts as a waveguide, channeling light through the stream.
 
The laser light is also source of a background noise that can cloud the signal, Persichetti said, so the amount of light that gets trapped in the jet was minimized by firing the laser beam at an angle perpendicular to the water stream.
 
After traveling 16 mm, the jet enters a small pipe containing an optical fiber, which collects the fluorescent light signals. The water is pumped back to recirculate through the nozzle, allowing the instrument to analyze even a small sample for an extended period of time.
 
The device was tested with varying amounts of some of the main pollutants of ground water - soil contaminants such as benzene, toluene, and xylene (together called BTX), and polycyclic aromatic hydrocarbons, which are hazardous, carcinogenic chemicals found in tar and petroleum. Persichetti and colleagues found that the device was extremely sensitive: It could detect pollutant levels even lower than those allowed by the Environmental Protection Agency (EPA). The instrument could also sense Bacillus subtilus, a harmless bacterium similar to the one that causes anthrax.
 
The current device is fitted with a spectrophotometer to measure the optical signatures of specific chemicals. To make the device even cheaper and smaller for future commercialization in water-safety testing, the researchers plan to replace the laser with an LED and to replace the spectrophotometer with a simpler and less expensive setup that would include a filter to remove unwanted background light, and a photodiode, which converts light into electricity, to detect the signal.
 
In addition to water-safety applications, Persichetti said, future instruments can be designed with more sophisticated sensors to distinguish between a variety of chemicals or bacterial cells for biological and medical research.
 
The paper, ¡°High sensitivity UV fluorescence spectroscopy based on an optofluidic jet waveguide,¡± appears in Optics Express.
 
¨Ï±Û·Î¹ú¹°»ê¾÷Á¤º¸¼¾ÅÍ(www.waterindustry.co.kr) ¹«´ÜÀüÀç ¹× Àç¹èÆ÷±ÝÁö
ÀÌÀü±Û [½º¿þµ§] ±âÈĺ¯È­·Î ÀÎÇÑ »ç¸Á·ü Áõ°¡
´ÙÀ½±Û [º£¿Ã¸®¾Æ] ¾Æ½Ã¾Æ »ê¾÷±â¼ú&±³À°¼¾ÅÍ ÁØ°ø½Ä °³ÃÖ
±Û·Î¹ú¹°»ê¾÷Á¤º¸¼¾ÅÍ.   ¼¾ÅÍÀå : ¹èö¹Î
ÁÖ¼Ò : ¼­¿ï½Ã ¼ÛÆı¸ »ïÀüµ¿ 72-3 À¯¸²ºôµù 5Ãþ TEL (02) 3431-0210   FAX (02) 3431-0260   E-mail waterindustry@hanmail.net
COPYRIGHT(C) 2012 ±Û·Î¹ú¹°»ê¾÷Á¤º¸¼¾ÅÍ. ALL RIGHT RESERVED.